power pump selection

*Oil flow
  • Determined by motor size
  • Directly affects electric power requirements
  • Determines cylinder or tool speed
**Duty cycle
  • Extended applications require more than one hour of interrupted pump use
  • Intermittent would be used less than one hour of continuous pump use
***Portability

Portable

  • ergonomic handles
  • flexible power requirements

Stationairy

  • mounting options
  • Normally requires stable power supply.

 

 

Oil
Flow *
Low
( 20 in3/min)
Medium
(60 - 200 in3/min)
High
(463 in3/min)
Usable
Oil
0.5 - 1.0
gallon
1.5
gallon
1.0 - 10.0
gallon
1.0 - 10.0
gallon
1.0 - 10.0
gallon
25
gallon
Duty
Cycle**
Intermittent Extended Intermittent Extended Extended  Extended
Portable ***  Portable  Stationary  Portable Stationary  Stationary Stationary
Recom-
mended
Pump
PU-Series Economy PE-Series Submerged ZU4 series ZE3-, ZE4- and ZE5-Series ZE6-Series  PE-8000 Series