MVP, WVP, V-series, sequence valves

  • Pressure dependent sequence control
  • Direct accurate pressure setting

MVPM-5 and WVP-5

  • Pressure setting between 500 - 5000 psi for secondary circuit is secured with lock nut
  • Manifold mounting ports

V-2000

  • Pressure setting between 200 - 2000 psi for secondary circuit
  • Flag indicator appears everytime the valve is operated

 

Pressure
Adjustment
Range
Maximum
Pressure
Maximum
Oil Flow
Model
Number
Oil
Ports
Operating
Pressure

Check Valve
Weight
psi psi in3/min psi pound
200-2000 2000 250 V-2000 1/8”-27 NPT 2.0
500-5000 5000 366 MVPM-5 G 1/4” 20 2.9
500-5000 5000 366 WVP-5 1/8”-27 NPT 20 1.8

 

Seal material: Buna-N.